Key result
Right vertical infra-axillary incision for MVR demonstrates safety with ~0.4% hospital mortality.
Why the study?
Does the right vertical infra-axillary incision provide safe and effective outcomes in patients undergoing mitral valve replacement?
Observational (n=256)
No
Does the right vertical infra-axillary incision provide safe and effective outcomes in patients undergoing mitral valve replacement?
The right vertical infra-axillary incision is a safe and feasible minimally invasive approach for mitral valve replacement with favorable clinical outcomes.
RVIAI may offer a cosmetic alternative for mitral valve replacement; leaves open the need for comparative trials before wider use.
BACKGROUND: As the physiologic results of valve surgery have improved dramatically in recent years, the cosmetic effect of the procedure gains increased attention, and various alternatives to the standard median sternotomy have been developed for mitral valve surgery. We report a new minimally invasive and cosmetic approach for mitral valve replacement. METHODS: From December 2003 to December 2009, the right vertical infra-axillary incision (RVIAI) was employed to perform mitral valve replacement in 256 patients. 62.9% patients had replaced mechanical valve, others were bioprosthetic valve, at the same time 28.1% patients received tricuspid valvuloplasty. RESULTS: There were one hospital death in this series due to multiple organ failure, one reoperation for bleeding and one incision infection. Mean follow-up duration was 42.8 months (range, 3 to 72), and follow-up rate was 94%. There were no paravalvular leaks or late death during the follow up. CONCLUSIONS: The RVIAI can be performed with favorable cosmetic and clinical results. It provides a good alternative to standard median sternotomy for MVR in selected patients.
No takes yet. Share an insight, caveat, or question.
Li et al. (2010) conducted an observational in Mitral valve disease (n=256). Right vertical infra-axillary incision (RVIAI) was evaluated on Hospital death. The right vertical infra-axillary incision for mitral valve replacement was performed safely in 256 patients, resulting in one hospital death (0.4%) and no late deaths or paravalvular leaks over a mean follow-up of 42.8 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: