Key result
New UV spectrophotometric methods simultaneously estimate Efonidipine and Chlorthalidone with ~98% accuracy.
Why the study?
Development of a quality control method is required for the accurate analysis of efonidipine hydrochloride ethanolate and chlorthalidone used in the management of hypertension.
Two simple, precise, and economical UV spectrophotometric methods were successfully developed and validated for the simultaneous estimation of Efonidipine and Chlorthalidone in synthetic mixtures.
Answers are grounded in this paper and cite their sources.
Supports economical simultaneous assay of these antihypertensives; extends validated UV methods to their combination in synthetic mixtures.
Efonidipine Hydrochloride Ethanolate and Chlorthalidone is used in management of hypertension and under clinical phase 3 study. The development of quality control method is required for accurate analysis of both drugs. Two simple, precise and economical UV spectrophotometric methods have been developed for the simultaneous estimation of Efonidipine Hydrochloride Ethanolate and Chlorthalidone in their synthetic mixture. Method I is simultaneous equation method (Vierodt’s Method), which is based on measurement of absorption at 251 and 227 nm i.e. λmax of Efonidipine Hydrochloride Ethanolate and Chlorthalidone, respectively. Method II is first order derivative was based on the measurement of absorbance of Efonidipine Hydrochloride Ethanolate measure at 283.2 nm (ZCP of Chlorthalidone) and absorbance of Chlorthalidone measure at 250.8 nm (ZCP of Efonidipine Hydrochloride Ethanolate). Linearity was observed in the concentration range of 6.4-38.4 µg.mL-1 for Efonidipine hydrochloride ethanolate and 2-12 µg.mL-1 for Chlorthalidone using methanol as a solvent. The accuracy of methods was assessed by recovery studies and was found to be within range of 98-102% for both the drugs. Precision of the methods was estimated by repeatability and intermediate precision studies. The % RSD values were found to be less than 2, proving methods were precise. Two methods were compared using F- test. The results were validated statistically as per ICH Q2 R1 guideline and were found to be satisfactory.
No takes yet. Share an insight, caveat, or question.
Solanki et al. (2022) studied Hypertension. UV spectrophotometric methods was evaluated on Accuracy and precision of the analytical methods. Two UV spectrophotometric methods were successfully developed and validated for the simultaneous estimation of Efonidipine hydrochloride ethanolate and Chlorthalidone, demonstrating 98-102% accuracy.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: