The aim of our study was to determine whether a subchondral or a capital position of the thread of the gliding screw provided the best fixation. A pull-out test was performed on pairs of femoral neck cadaver specimens. The capital position of the thread provided the best fixation in all the pairs. A correlation was found between bone mineral content of the femoral heads and the holding power of the screws in both positions.
No takes yet. Share an insight, caveat, or question.
Iversen et al. (1988) studied this question.