Key result
Bio-physical modeling demonstrates a sigmoidal rather than linear dose-response for CVD after heart irradiation.
Why the study?
Does the dose-response relationship for cardiovascular disease after radiotherapy depend on the irradiated volume?
Does the dose-response relationship for cardiovascular disease after radiotherapy depend on the irradiated volume?
Epidemiological studies predicting a linear dose-response for cardiovascular disease after radiotherapy may not apply to all irradiation volumes, suggesting bio-physical models should be used to predict complications.
Answers are grounded in this paper and cite their sources.
Questions linear CVD risk models across heart irradiation volumes; challenges epidemiology and leaves bio-physical validation open.
The probability for a complication after radiotherapy is usually a function of dose and volume in the organ or tissue of interest. In most epidemiological studies the risk for a complication is stratified in terms of dose, but not irradiated volume. We show that the obtained risk cannot generally be applied to radiotherapy patients.The epidemiological data of Darby et al. (N Engl J Med 368:2527, 2013) who found a linear relationship between the excess relative risk of major coronary events as function of mean heart dose in patients treated with tangential breast irradiation are analyzed. We have used the relative seriality model for a partly irradiated heart ("a lot to a little") which models radiation therapy using two tangential fields. The relative seriality model was then used to predict NTCP of cardiovascular disease for a homogenously irradiated heart ("a little to a lot"). The relative seriality model was fitted to the data of Darby et al. (N Engl J Med 368:2527, 2013) for tangential breast irradiation. For the situation "a little to a lot" it was found that the dose-response relationship is sigmoidal and contradicts the findings of Darby et al. (N Engl J Med 368:2527, 2013). It was shown in this work that epidemiological studies which predict a linear dose-response relationship for cardiovascular disease can be reproduced by bio-physical models for normal tissue complication. For irradiation situations which were not included in the epidemiological studies, e.g. a homogenous irradiation of the heart ("a little to a lot") the dose-response curve can be different. This could have consequences whether or not IMRT should be used for treating breast cancer. We believe that the results of epidemiological studies should not be generally used to predict normal tissue complications. It is better to use such data to optimize bio-physical models which can then be applied (with caution) to general treatment situations.
No takes yet. Share an insight, caveat, or question.
Schneider et al. (2017) conducted a review in Cardiovascular disease after radiotherapy. Radiotherapy (mean heart dose) was evaluated on Normal tissue complication probability (NTCP) of cardiovascular disease. Bio-physical modeling demonstrates that the dose-response relationship for cardiovascular disease after homogenous heart irradiation is sigmoidal rather than linear, contradicting generalized linear predictions.
Synapse has enriched 10 related papers. Consider them for comparative context: