Key result
Breath-holding BOLD MRI produces reproducible signals at 1.5T and 3T despite smaller activation at 1.5T.
Why the study?
Little is known about the long-term reproducibility of BOLD signal change induced by breath-holding to estimate cerebrovascular reactivity and its reproducibility using a 1.5 T MRI system.
Is the BOLD signal change induced by breath-holding reproducible over short and long terms at 1.5 and 3 T MRI?
Observational (n=9)
Is the BOLD signal change induced by breath-holding reproducible over short and long terms at 1.5 and 3 T MRI?
BOLD signal response to breath-holding is a reproducible technique for assessing cerebrovascular reactivity over time at both 1.5 and 3 T MRI.
BH-BOLD CVR shows acceptable long-term reproducibility at 1.5 T and 3 T; leaves open prospective validation before routine clinical monitoring in cerebrovascular disease.
Cerebrovascular reactivity (CVR) can give insight into the cerebrovascular function. CVR can be estimated by measuring a blood-oxygen-level-dependent (BOLD) response combined with breath-holding (BH). The reproducibility of this technique has been addressed and existing studies have focused on short-term reproducibility using a 3 T magnetic resonance imaging (MRI) system. However, little is known about the long-term reproducibility of this procedure and the corresponding reproducibility using a 1.5 T MRI system. Here, we systematically examined the short- and long-term reproducibility of BOLD responses to BH across field strengths. Nine subjects participated in three MRI sessions separated by 30 minutes (sessions 1 and 2: short term) and 68-92 days (sessions 1 and 3, long term) at both 1.5 and 3 T MRI. Our findings revealed that significant differences between field strengths were detected in the activated gray matter volume and BOLD signal change (both P < 0.001), with smaller magnitudes at 1.5 T. However, activation patterns were reproducible, independent of the time interval, brain region or field strength. All interscan coefficient of variation values were below the 33% fiducial limit, and the intraclass correlation coefficient values were above 0.4, which is usually considered the acceptability limit in functional studies. These findings suggest that the response of BOLD signal to BH for assessing CVR is reproducible over time at 1.5 and 3 T. This technique can be considered a tool for monitoring longitudinal changes in patients with cerebrovascular diseases, and its use should be encouraged for clinical 1.5 T MRI systems.
No takes yet. Share an insight, caveat, or question.
Peng et al. (2019) reported an observational. Breath-holding during 1.5 T and 3 T MRI was evaluated on Differences between field strengths in activated gray matter volume and BOLD signal change (p=<0.001). Breath-holding induced BOLD signal changes were reproducible over short and long terms at both 1.5 and 3 T MRI, although activation magnitudes were smaller at 1.5 T (P<0.001).