PURPOSE: To describe the technique of carbon dioxide (CO2) flushing of thoracic stent-grafts to reduce the risk of cerebral air embolism. TECHNIQUE: To remove room air, thoracic stent-grafts were preoperatively flushed 2 minutes with carbon dioxide from a cylinder connected to the flushing chamber of the captor valves of Zenith custom-made endografts; this was followed by the standard saline flush. Thirty-six patients undergoing thoracic endovascular aortic repairs (TEVAR) involving the ascending aorta and the aortic arch received CO2-flushed Zenith endografts. One patient with a highly calcified arch experienced a minor stroke. CONCLUSION: Arterial air embolism is a potentially underappreciated problem of aortic endografting, especially in the proximal segments of the aorta. CO2 flushing may have the potential to reduce air embolization during TEVAR.
No takes yet. Share an insight, caveat, or question.
Kölbel et al. (2016) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: