This is the authors' abstract. We don't add key points for this paper.
AI-3000K is a semi-empirical IR line list constructed for hot CO2 spectra analysis and simulation up to 3000 – 4000 K. Compared to previously published Ames-1000K and UCL-4000, it represents a major upgrade, utilizing a new algorithm for optimization and including the latest improvements in potential energy surface (PES), dipole moment surface (DMS), and room temperature IR line list (Ames-2021 296K). To maximize the success of introducing experimental based accurate line positions, a new PES (X01d) was refined with respect to >800 selected CDSD2019 [Tashkun et al. JQSRT (2019) 228, 124] energy levels in the range of 0 – 24,000 cm−1, with σrms = 0.5 – 0.7 cm−1. Most differences between the X01d PES based levels and CDSD2019 energies are within ± 2 cm−1. A new DMS is fitted from extrapolated CCSD(T)/aug-cc-pV(T,Q,5)Z dipole calculations, with σrms = 5.1 × 10−6 au for 11,155 geometries up to 40,000 cm−1, denoted Ames-2021–40K. Compared to the best available Ames-2021 DMS and room temperature IR line list [Huang et al J. Phys. Chem. A (2022) 126, 5940], the relative intensity differences are expected to be ∼ 1 ‰. The line position accuracy of ''X01d + Ames-2021–40K'' IR line list is significantly improved by adopting CDSD2019 energy levels up to 24,000 cm−1 (J ≤ 150). The Einstein A21 coefficients for E' < 15,000 cm−1 transitions are replaced by more accurate values from the Ames-2021 296K IR line list. In short, the AI-3000K is the X01d PES and Ames-2021–40K DMS based line list enhanced with the A21 of Ames-2021 296K line list and CDSD energy levels. It provides continuous coverage from 0 to 20,000 cm−1 for the four most abundant isotopologues: 12C16O2 (6 2 6), 13C16O2 (6 3 6), 16O12C18O (6 2 8), and 16O12C17O (6 2 7). The impacts of isotopologue and E'/E'' cutoffs have been examined. Intensity convergence (not accuracy) of AI-3000K line list is quantitatively estimated in 1 cm−1 bins. It is better than 99% in the whole range of 0 – 20,000 (or 10,000) cm−1 at 1000 K (or 2000 K), or better than 90% in the whole range of 0 – 15,000 (or 9000) cm−1 at 2000 K (or 3000 K), respectively. Convergence beyond 3000 K will require a new PES and DMS for E' > 40,000 cm−1. The AI-3000K and HITEMP based IR simulations are compared to high resolution shock tube experiments for CO2-Ar mixture up to 2000 K. With line position accuracy comparable to that of HITEMP, AI-3000K IR line list yields better agreements at more frequencies. Potential sources of discrepancies with experiment are discussed.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: