A method suitable for the determination of unmetabolized polycyclic aromatic hydrocarbons (PAHs) excreted at trace levels (ng/L) in human urine for the monitoring of exposure of the general population to PAH contamination was developed. PAHs were determined, after enrichment by solid-phase extraction on polyurethane foam (PUF) chips, by HPLC with fluorescence detection. Different parameters affecting analyte extraction to the PUF, including urine salting-out and organic additives, and optimization of conditions for clean-up and desorption have been investigated. Optimized conditions were 40 mL acidified urine sample, added with magnesium sulfate, tetrahydrofuran and a 2 cm3 PUF chip, and extracted by shaking at 30 rpm for 1 h at ambient temperature. Desorption was performed, after a clean-up step with diluted sodium hydroxide, using a small amount of diethyl ether. The recovery of PAH congeners from spiked urines was >90% in the 2-100 ng/L range; the detection limit was 0.1-0.5 ng/L, depending on the considered PAH congener; day-to-day precision, at 50 ng/L native PAH content, was CV = 10-20%. The proposed technique provides a simple, economical and effective procedure for the determination of trace amounts of unmetabolized PAHs excreted in human urine spot samples.