Least-squares optimization smoothing and nonlinear transformation improves QRS detection accuracy over state-of-the-art techniques.
Why the study?
Does a novel least-squares-optimisation-based smoothing and nonlinear transformation technique improve QRS detection accuracy in ECG signals compared to existing techniques?
Does a novel least-squares-optimisation-based smoothing and nonlinear transformation technique improve QRS detection accuracy in ECG signals compared to existing techniques?
A novel QRS-preserving filtering technique using least-squares optimization and nonlinear transformation improves the accuracy of both offline and real-time QRS detection in ECG signals.
Answers are grounded in this paper and cite their sources.
May aid QRS detection amid spectral noise; leaves open prospective validation before clinical adoption.
Detection of QRS complexes in ECG signals is required for various purposes such as determination of heart rate, feature extraction and classification. The problem of automatic QRS detection in ECG signals is complicated by the presence of noise spectrally overlapping with the QRS frequency range. As a solution to this problem, we propose the use of least-squares-optimisation-based smoothing techniques that suppress the noise peaks in the ECG while preserving the QRS complexes. We also propose a novel nonlinear transformation technique that is applied after the smoothing operations, which equalises the QRS amplitudes without boosting the supressed noise peaks. After these preprocessing operations, the R-peaks can finally be detected with high accuracy. The proposed technique has a low computational load and, therefore, it can be used for real-time QRS detection in a wearable device such as a Holter monitor or for fast offline QRS detection. The offline and real-time versions of the proposed technique have been evaluated on the standard MIT-BIH database. The offline implementation is found to perform better than state-of-the-art techniques based on wavelet transforms, empirical mode decomposition, etc. and the real-time implementation also shows improved performance over existing real-time QRS detection techniques.
No takes yet. Share an insight, caveat, or question.
Sharma et al. (2017) studied ECG signal analysis. Least-squares-optimisation-based smoothing and nonlinear transformation technique vs. State-of-the-art techniques (wavelet transforms, empirical mode decomposition) was evaluated on QRS detection performance. The proposed least-squares-optimisation-based smoothing and nonlinear transformation technique for QRS detection demonstrated improved performance over state-of-the-art techniques on the MIT-BIH database.
Synapse has enriched 10 related papers. Consider them for comparative context: