Comparative evaluation demonstrates distinct trade-offs between harmonic attenuation and power loss in avionics power converters, highlighting topology-specific design priorities.
This paper presents a comparative analysis of three magnetic-integrated LCL-derived filter configurations for suppressing high-frequency switching harmonics in avionics power-conversion systems: the integrated LLCL filter, the magnetic-integrated multi-trap LCL filter, and the magnetic-integrated trapped-LCL filter. The high-frequency harmonics considered in this study originate primarily from the pulse-width-modulated (PWM) switching process and can increase current distortion, electrical and magnetic losses, component stress, and the potential for electromagnetic interference in aircraft electrical systems. To enable a consistent comparison, the three filter configurations are evaluated within a unified analytical framework under common system-level operating conditions, while retaining their topology-specific passive and magnetic parameters according to their respective design requirements. The framework distinguishes aggregate total harmonic distortion (THD) from attenuation at targeted switching-frequency bands and incorporates the effects of resonant branches and magnetic coupling. The simulated current THD values of the LLCL, multi-trap LCL, and trapped-LCL filters are 0.82%, 0.84%, and 1.13%, respectively, while their estimated total filter losses are 24.98 W, 59.74 W, and 40.49 W. At the 1 kW operating point, these losses correspond to 2.50%, 5.97%, and 4.05% of rated power, respectively. The results show that the LLCL filter achieves the lowest aggregate THD and estimated loss under the investigated conditions, whereas the multi-trap and trapped-LCL configurations provide additional capability for targeted attenuation of selected switching-frequency components through their resonant structures. Hardware-in-the-loop (HIL) results further support the electrical filtering and dynamic behavior of the investigated concepts. The comparison demonstrates that minimum THD, minimum loss, targeted switching-harmonic attenuation, and magnetic integration are distinct design objectives; therefore, topology selection should be based on the specific requirements and constraints of the intended avionics application.
No takes yet. Share an insight, caveat, or question.
Al‐Barashi et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: