The authors examined the modifications of some markers of platelet activation after contact with biomaterials. Glycoprotein GMP-140 (CD62) was evaluated by flow cytometry; beta-thromboglobulin (beta-TG) and thromboxane B2 (TXB2) were determined by radioimmunoassay. Polyethylene terephthalate (PET) induced a remarkable platelet adhesion and a significant increase in beta-TG and TXB2, with no increase in CD62 on the nonadherent platelets. Pyrolytic carbon-coated PET (PC) did not induce platelet adhesion after 15 min of contact, but a significant increase in CD62 was detected. After 30 min a significant increase in platelet adhesion as well as the release of beta-TG and TXB2 were noted. The increase was lower than that observed for uncoated PET, and after 30 min of contact with PC the increase no longer was observed.
No takes yet. Share an insight, caveat, or question.
Cenni et al. (1997) studied this question.