Key result
Robotic mitral valve surgery demonstrates safety in prior sternotomy patients with 0% 30-day mortality.
Why the study?
Despite increasing minimally invasive approaches to mitral valve surgery after prior sternotomy, outcomes of the robotic approach in this population have not been examined.
Is the robotic approach to mitral valve surgery safe and feasible in patients with a prior sternotomy?
Observational (n=21)
Is the robotic approach to mitral valve surgery safe and feasible in patients with a prior sternotomy?
Robotic mitral valve surgery is safe and feasible in selected patients with a prior sternotomy when performed by experienced surgeons.
Robotic mitral reoperation appears feasible with low morbidity in selected patients; leaves open broader adoption pending prospective data.
Objective: Despite the recent increase in the use of minimally invasive approaches to mitral valve surgery in patients with a prior sternotomy, the outcomes of the robotic approach to mitral valve surgery in this patient population have not been examined. Methods: We retrospectively reviewed 342 consecutive patients who underwent mitral valve surgery after a prior sternotomy between 2013 and 2020, in which the robotic approach was used in 21 patients (6.1%). We reviewed the clinical details of these 21 patients. Results: The median age was 71 years [interquartile range 64.00, 74.00 years], and mean Society of Thoracic Surgeons Predicted Risk of Mortality was 4.2% ± 3.8%. The indication for mitral valve surgery was degenerative mitral valve disease in 33.3% (7/21), functional disease in 28.6% (6/21), mixed disease in 4.8% (1/21), rheumatic disease in 9.5% (2/21), and failed repair for degenerative disease in 23.8% (5/21). No cases required conversion from robotic assistance to alternative approaches, there were no intraoperative deaths, and intraoperative transesophageal echocardiogram confirmed complete elimination of mitral regurgitation in 90.5% (19/21) of cases. Thirty-day mortality was 0.0% (0/21), and 1-year mortality was 4.8% (1/21). There were no strokes or wound infections at 30 days, and 14.3% (3/21) of patients received intraoperative blood product transfusions. Conclusions: The results of this retrospective review suggest that the robotic approach to mitral valve surgery in patients with a prior sternotomy is safe in experienced hands. Although some centers have considered prior sternotomy a relative contraindication to robotic mitral valve surgery, this approach is feasible and can be considered an option for experienced surgeons.
No takes yet. Share an insight, caveat, or question.
Meidan et al. (2022) conducted an observational in Mitral valve disease requiring surgery after prior sternotomy (n=21). Robotic mitral valve surgery was evaluated on 30-day mortality. Robotic mitral valve surgery in patients with a prior sternotomy was safe and feasible, resulting in 0% 30-day mortality, 4.8% 1-year mortality, and no intraoperative deaths.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: