Fuel cell electric vehicles (FCEVs) require thermal management to keep the stack temperature within an allowable range, but cooling auxiliaries (pump/fan) consume parasitic power that can degrade hydrogen fuel economy. This study proposes an adaptive-bias near-open valve control strategy that reduces cooling parasitic power while preserving temperature regulation. The controller uses the parasitic-power cost to update a small valve bias under fuel-cell-load gating and temperature/overcooling constraints, and applies first-order lag and slew-rate limits to suppress chattering and repeated saturation. The strategy was evaluated using a validated, control-oriented 100 kW-class light-duty FCEV integrated model over UDDS, FTP-75, HWFET, and US06, with fuel economy compared using SAE J2572 SOC correction. Across all cycles, the proposed controller reduced parasitic power and improved SOC-corrected fuel economy relative to baseline PI valve control by 2.05% (UDDS), 2.55% (FTP-75), 7.22% (HWFET), and 2.13% (US06). These results suggest that cost-driven valve operating-point adaptation can reduce cooling parasitic power and improve SOC-corrected fuel economy within the tested driving cycles, while retaining a PI-compatible supervisory structure.
No takes yet. Share an insight, caveat, or question.
Han et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: