Initial (i.e., unaged) adhesion, as well as adhesion after seven day, 60°C water immersion and six week scab corrosion accelerated environmental exposures, has been assessed for five different one and two-part epoxy adhesives, bonded to three different types of galvanized steel substrates. We have shown that adhesion, as measured by lap shear strength, is specific to the galvanized substrate type. In general, for a given adhesive, adhesion to “hot-dipped” galvanized substrates is harder to achieve and maintain under accelerated environmental exposure than is adhesion to “electroplated” galvanized. Also, for a given type of galvanized steel, the one-part epoxies evaluated generally showed higher initial strengths, as well as better strength retention under environmental exposure than did the two-part epoxies.
No takes yet. Share an insight, caveat, or question.
Foster et al. (1987) studied this question.