Unicompartmental knee arthroplasty using the Marmor modular knee prosthesis or, later, the Richards Modular II prosthesis in a series of 72 knees (60 patients) is reviewed, with an average follow-up period of four years (minimum, 2 years). Pain relief was rated as excellent in 90% of the knees. The average range of motion was improved after operation. No deep infections were encountered. Only one knee in the series has required further surgery, for patellofemoral disease.
No takes yet. Share an insight, caveat, or question.
Bae et al. (1983) studied this question.