Key result
Heart-ID framework improves PCG identity recognition and lowers error rates versus previous systems.
Why the study?
Existing phono‐cardio‐gram biometric authentication systems primarily use mel‐frequency and linear frequency cepstral features, but improved feature extraction methods are needed for better human identity recognition using heart sounds.
Modifying mel-frequency cepstral features improves the accuracy of human identity recognition using heart sound signals.
New PCG biometric framework with modified cepstral features shows promise; leaves open validation in diverse cohorts before adoption.
This study presents a new framework for human identity recognition using heart sound signals. The proposed framework is based on extracting cepstral features from heart sound signals, which are known as phono‐cardio‐gram (PCG). Two well‐known cepstral features have been adopted in most of the previously implemented PCG biometric authentication systems; namely, mel‐frequency and linear frequency cepstral features. In this study, two more cepstral features are proposed based on modifying the mel‐frequency cepstral features. The first one is based on modifying the mel‐frequency equation to increase the non‐linearity of the triangular filters in the frequency range of the PCG signal. The other is based on replacing mel‐scaled triangular filters with wavelet packet filters where a non‐linear filter bank structure is designed using wavelet packet decomposition to select the appropriate bases for extracting discriminant features. The proposed system uses wavelet de‐noising for pre‐processing and linear discriminant analysis for classification. The proposed system is evaluated on two databases; one consists of 21 users (BioSec. database) and the other consists of 206 users (HSCT‐11 database). Moreover, the proposed system is compared with previous systems that used the same databases. On the basis of the achieved results over the two databases, the two proposed cepstral features achieved higher correct recognition rates and lower error rates in identification and verification modes, respectively.
No takes yet. Share an insight, caveat, or question.
Abbas et al. (2016) studied Human identity recognition (n=227). Modified mel-frequency cepstral features (Heart-ID) vs. Previous systems using standard cepstral features was evaluated on Correct recognition rates and error rates in identification and verification modes. The proposed Heart-ID framework using modified mel-frequency cepstral features achieved higher correct recognition rates and lower error rates compared to previous systems.