Key result
A smaller indexed effective orifice area (EOAI) after aortic valve replacement was associated with a significantly increased risk of cardiac death (HR 0.32, p=0.022).
Why the study?
Does a smaller indexed effective orifice area (EOAI) increase the risk of cardiac death in patients after aortic valve replacement?
Cohort (n=645)
Does a smaller indexed effective orifice area (EOAI) increase the risk of cardiac death in patients after aortic valve replacement?
Hazard Ratio: 0.32
p-value: p=0.022
Actual in vivo measurement of indexed effective orifice area via postoperative echocardiography demonstrates that smaller EOAI significantly increases the risk of mid-term cardiac mortality after aortic valve replacement.
BACKGROUND: There has been ongoing controversy as to whether prosthesis-patient mismatch (PPM, defined as indexed effective orifice area (EOAI) <0.85 m(2)/cm(2)) influences mortality after aortic valve replacement (AVR). In most studies, PPM is anticipated by reference tables based on mean EOAs as opposed to individual assessment. These reference values may not reflect the actual in vivo EOAI and hence, the presence or absence of PPM may be based on false assumptions. OBJECTIVE: To assess the impact of small prosthesis EOA on survival after aortic valve replacement AVR. METHODS: 645 patients had undergone an AVR between 2000 and 2007 entered the study. All patients underwent transthoracic echocardiography for determination of the actual EOAI within 6 months postoperatively. In order to predict time from surgery to death a proportional hazards model for competing risks (cardiac death vs death from other causes) was used. EOAI was entered as a continuous variable. RESULTS: PPM occurred in 40% of the patients. After a median follow-up of 2.35 years, 92.1% of the patients were alive. The final Cox regression model showed a significantly increased risk for cardiac death among patients with a smaller EOAI (HR=0.32, p=0.022). The effect of EOAI on the 2-5 year mortality risk was demonstrated by risk plots. CONCLUSIONS: In contrast to previous studies these EOAI values were obtained through postoperative echocardiography, substantially improving the accuracy of measurement, and the EOAI was modelled as a continuous variable. There was a significantly improved survival for larger EOAIs following AVR. Strategies to avoid PPM should become paramount during AVR.
No takes yet. Share an insight, caveat, or question.
Bleiziffer et al. (2010) conducted a cohort in Aortic valve replacement (n=645). Smaller indexed effective orifice area (EOAI) vs. Larger EOAI was evaluated on Cardiac death (HR 0.32, p=0.022). A smaller indexed effective orifice area (EOAI) after aortic valve replacement was associated with a significantly increased risk of cardiac death (HR 0.32, p=0.022).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: