Pipeline corrosion is an important issue that threatens the pipeline safety operation; therefore, the corrosion monitoring is essential. Based on the optical frequency domain reflectometry technology, which features distributed strain measurement with high resolution and high precision, a new method of pipeline internal corrosion monitoring is proposed to simultaneously locate corrosion and to evaluate corrosion severity. To verify the effectiveness and accuracy of this method, a series of tests were conducted including uniform corrosion test and local corrosion tests. These test results demonstrate that the corrosion location and corrosion severity evaluation can be achieved via the proposed distributed strain measurement, providing a valuable approach for pipeline corrosion monitoring.