Key result
Use of 5F sheaths compared to 6F sheaths did not significantly reduce the risk of radial artery occlusion (1.6% vs 2.1%, p=0.44) or time to TR-band removal (101 vs 105 min, p=0.07).
Why the study?
Whether minimizing equipment size to 5F sheaths compared to 6F sheaths further reduces bleeding, time to hemostasis, and radial artery occlusion during transradial coronary procedures was uncertain.
Does the use of 5F sheaths compared to 6F sheaths reduce time to hemostasis and risk of radial artery occlusion in patients undergoing coronary angiography or intervention?
RCT (n=3,600)
randomized
Does the use of 5F sheaths compared to 6F sheaths reduce time to hemostasis and risk of radial artery occlusion in patients undergoing coronary angiography or intervention?
The use of 5F sheaths for transradial coronary procedures does not significantly reduce the risk of radial artery occlusion compared to 6F sheaths, though it may shorten hemostasis time in as-treated analysis.
BACKGROUND: Transradial access is the preferred approach for coronary procedures due to lower complication rates compared to femoral access. However, minimizing equipment for radial access may further reduce bleeding and radial artery occlusion (RAO). AIMS: This study assessed whether the use of 5F sheaths, compared to 6F sheaths, reduces time to hemostasis and the risk of RAO in patients undergoing diagnostic coronary angiography and/or coronary intervention. METHODS: 3600 patients were randomized to 5F or 6F sheaths, except when operators preferred 6F sheaths. TR-band deflation and removal times were recorded, and radial artery patency was assessed at discharge using the reverse Barbeau test, with Types C and D indicating RAO. RESULTS: 942 patients were randomized to 5F and 945 to 6F sheath. In 1713 patients, 6F sheaths were chosen up front by the operator. In intention-to-treat analysis no significant differences were observed between the randomized groups in time to TR-band removal (101 vs. 105 min, p = 0.07), or RAO (1.6 % vs. 2.1 %, p = 0.44). A significant crossover to 6F sheaths occurred in the 5F group. In as-treated analyses, TR-band removal times were shorter with 5F compared to 6F and operator-preferred 6F sheaths (98.5 min, 105 min, 111 min, P < 0.01). No significant differences in RAO risk were observed between groups (1.8 %, 1.9 %, 1.2 %, P = 0.34). CONCLUSIONS: Although 5F sheaths reduced time to TR-band deflation and removal compared to 6F sheaths, no significant reduction in RAO was observed. High crossover rates suggest operator preference remains a key factor in sheath selection.
No takes yet. Share an insight, caveat, or question.
Nielsen et al. (2025) conducted an RCT in diagnostic coronary angiography and/or coronary intervention (n=3,600). 5F sheaths vs. 6F sheaths was evaluated on Radial artery occlusion (RAO) (p=0.44). Use of 5F sheaths compared to 6F sheaths did not significantly reduce the risk of radial artery occlusion (1.6% vs 2.1%, p=0.44) or time to TR-band removal (101 vs 105 min, p=0.07).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: