We have been developing Superconducting Fault Current Limiting Transformer (SFCLT), which has multifunction of both a superconducting transformer in a steady state as well as a superconducting fault current limiter in a fault condition. This paper introduces the progress in our SFCLT project since 1998, from Step-1 to the latest Step-5, with the concept, design, fabrication and test results of SFCLT. In the latest Step-5, we developed a 2 MVA, 22/6.6 kV class SFCLT with YBCO coated conductors and verified the fundamental function as a transformer, effective current limiting function as a fault current limiter, and recovery characteristics after the fault clearance with its operational criterion.
No takes yet. Share an insight, caveat, or question.
Hayakawa et al. (2010) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: