Simulation study demonstrates substantial energy reductions and net-positive electricity in a historic stone building, highlighting viable low-carbon heritage preservation.
Heritage buildings sit outside most national energy codes, yet Palestine alone hosts over 3000 historic structures whose 80–120 cm two-leaf stone construction is absent from any published, measurement-grounded retrofit dataset. A 19th-century three-storey heritage building (Qaser Morcos, Bethlehem; net floor area 406 m2, volume 2100 m3) was investigated through (i) in situ measurements (heat-flux meter to ISO 9869-1; infrared thermography; illuminance survey); (ii) a Heritage Building Information Model (H-BIM) built in DesignBuilder v7 with EnergyPlus 25.1 and the Jerusalem-centre typical meteorological year weather file, with end-uses other than heating, ventilation and air conditioning (HVAC) calibrated to three years of measured electricity records and the HVAC baseline comfort-normalised; (iii) a Heritage Impact Assessment per EN 16883:2017; and (iv) a 5000-run Monte Carlo uncertainty analysis on five envelope and system inputs. Two retrofit stages were evaluated: Stage 1 (passive and renewable measures—roof insulation, shading elements, LED lighting with motion sensors, solar water heating, and a 20 kWp photovoltaic system) and Stage 2 (deep envelope and system upgrade—Stage 1 plus triple-glazing, Variable Refrigerant Flow system, and a 17.5 kWp photovoltaic system). Predicted final (delivered) electricity intensity falls from 94.5 to 71.2 kWh/m2·y under Stage 1 (−24.7%) and to 63.3 kWh/m2·y under Stage 2 (−33.0%; 90% Monte Carlo uncertainty interval 59.0–70.4 kWh/m2·y), both well below the Palestinian Energy Building Code limit of 120 kWh/m2·y. On-site generation exceeds post-retrofit electrical demand under both stages, yielding a net-positive electrical balance. Direct carbon dioxide emissions fall by 6.84 t/y (−33%) at Stage 2. Discounted paybacks are 4.6 y (Stage 1) and 10.4 y (Stage 2), with internal rates of return of 24.7% and 11.7%. All proposed interventions received project-team consensus scores of ≥3/5 against EN 16883:2017 heritage-impact criteria. This study delivers a replicable simulation-based workflow for the energy assessment and heritage-compatible retrofit of thick-walled Palestinian stone buildings and one of the first field-informed heritage-retrofit datasets from the Levant.
No takes yet. Share an insight, caveat, or question.
Dwaikat et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: