The aim of the current study was to evaluate the effectiveness of three nonthermal light technologies (NUV-Vis, continuous UV, and HILP) on their ability to inactivate Escherichia coli K12 and Listeria innocua. E. coli K12 was selected as a representative microorganism for the enterohaemorrhagic foodborne pathogen E. coli O157:H7 and L. innocua as a surrogate microorganism for the common foodborne pathogen Listeria monocytogenes, respectively. The liquid matrix used for the disinfection experiments was a liquid matrix (MRD solution). The results of the present study show that the HILP treatment inactivated both E. coli and L. innocua more rapidly and effectively than either continuous UV-C or NUV-vis treatment. With HILP at 2.5 cm from the lamp, E. coli and L. innocua populations were reduced by 3.07 and 3.77 log10 CFU/mL, respectively, after a 5 sec treatment time, and were shown to be below the limit of detection (<0.22 log10 CFU/mL) following 30 sec exposure to HILP (106.2 J/cm(2)). These studies demonstrate the bactericidal efficacy of alternative nonthermal light technologies and their potential as decontamination strategies in the food industry.