PURPOSE: To evaluate continuous wear of a fluid-ventilated, gas-permeable scleral PROSE device using a standardized protocol as treatment for refractory persistent corneal epithelial defects in patients with severe ocular surface disease. METHODS: Retrospective review of eight eyes of seven consecutive patients with persistent epithelial defects refractory to traditional therapies. The standardized treatment regimen consisted of: (1) 24-hour-a-day PROSE wear until re-epithelialization was achieved, (2) brief daily device removal, cleaning, disinfection, and reservoir fluid replacement, (3) addition of a benzalkonium chloride (BAK)-free fourth-generation fluoroquinolone antibiotic drop to the reservoir, and (4) transition to long-term, daytime PROSE wear upon re-epithelialization. RESULTS: All eight eyes exhibited resolution of the persistent epithelial defect. No eyes developed microbial keratitis. Four eyes exhibited recurrences; all recurrences promptly responded to reinstitution of continuous wear. CONCLUSIONS: Continuous wear of a PROSE device, using a strictly standardized regimen, constitutes an effective, safe treatment option for refractory persistent epithelial defects.
No takes yet. Share an insight, caveat, or question.
Ciralsky et al. (2014) studied this question.