Key result
DBS and cochlear implants appear compatible when deactivated during microelectrode recordings.
Why the study?
An increasing number of DBS candidates have preexisting implanted electrical devices, raising concerns about safety and compatibility during DBS surgery.
Is deep brain stimulation safe and feasible in patients with preexisting cochlear implants?
Case Report (n=1)
Is deep brain stimulation safe and feasible in patients with preexisting cochlear implants?
Deep brain stimulation and cochlear implants can be safe and compatible in the same patient if necessary precautions, such as turning off the implants during surgery, are taken.
BACKGROUND/AIMS: As technology continues to advance for our aging population, an increasing number of deep brain stimulation (DBS) candidates will have preexisting implanted electrical devices. In this article, we discuss safe and successful DBS in a patient with Parkinson's disease (PD) and bilateral cochlear implants. METHODS: A 70-year-old male with PD and bilateral cochlear implants underwent successful microelectrode-guided DBS implantation into bilateral subthalamic nuclei (STN). The patient's cochlear implant magnets were removed and replaced in the outpatient clinic for preoperative MRI and stereotactic targeting. The cochlear implants were turned off intraoperatively for STN microelectrode recordings. RESULTS: Precise, MRI-guided stereotactic DBS implantation was possible. Intraoperative high-fidelity microelectrode recordings confirmed STN neurons with the cochlear implants turned off. These recordings were not possible with active cochlear implant devices. Our literature review describes the other approaches/techniques that have been used to manage DBS surgery in the setting of cochlear implants. CONCLUSIONS: Despite the risk of electrical interference between implanted medical devices, DBS and cochlear implants may be safe and compatible in the same patient if necessary precautions are taken.
No takes yet. Share an insight, caveat, or question.
Buell et al. (2015) conducted a case report in Parkinson's disease and bilateral cochlear implants (n=1). Deep brain stimulation (DBS) implantation was evaluated on Feasibility and safety of DBS implantation. Deep brain stimulation and cochlear implants may be safe and compatible in the same patient if necessary precautions, such as turning off cochlear implants during microelectrode recordings, are taken.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: