A novel glassy carbon electrode (GCE) modified with carbon-spheres has been fabricated through a simple casting procedure. The modified GCE displays high selectivity and excellent electrochemical catalytic activities towards dopamine (DA), serotonin (5-HT), and ascorbic acid (AA). In the co-existence system, the peak separations between AA and DA, DA and 5-HT, and AA and 5-HT are large up to 230, 180, and 410 mV, respectively. Differential pulse voltammetry (DPV) has been employed to simultaneously detect DA, 5-HT, and AA, and the linear calibration curves for DA, 5-HT, and AA are obtained in the range of 20.0-150.0 μM, 40.0-750.0 μM and 300.0-2,000.0 μM with detection limits (S/N = 3) of 2.0 μM, 0.7 μM and 0.6 μM, respectively. The proposed electrode has been applied to detect DA, 5-HT, and AA in real samples using standard addition method with satisfactory results.
No takes yet. Share an insight, caveat, or question.
Sheng et al. (2013) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: