The present work reports the test results of seven full-scale reinforced concrete slab-column edge connections strengthened against punching shear using different methods. In this study, three slabs contained openings in the vicinity of the column, and the other four were without openings. The dimensions of the slabs were 1,540×1,020×120 mm with square columns (250×250 mm). The openings in the specimens were square (150×150 mm) with the sides parallel to the sides of the column. The slabs were reinforced with an average reinforcement ratio of 0.75%. Except for the two reference slabs, two different strengthening techniques were considered. Technique I applies externally bonded fiber reinforced polymer (FRP) flexible sheets on the slab around the column in two schemes with one or two layers of FRP sheets glued to the tension face or both tension and compression faces of the slab. Both glass and carbon FRP sheets were considered. Technique II applies externally bonded FRP sheets using either the first or second scheme combined with installing steel bolts through holes across the slab thickness around the column. Based on the test results, it is concluded that the presence of FRP sheets and steel bolts substantially increased the punching capacity of the connections. Code design expressions were conservative in predicting the experimental results.
No takes yet. Share an insight, caveat, or question.
El-Salakawy et al. (2004) studied this question.