For optimizing the reaction conditions of 2-methyl-6-ethylaniline (MEA) degradation catalyzed by horseradish peroxidase (HRP), a response surface methodology with three factors and three levels was used in this research to establish a regression model, a ternary quadratic polynomial, in order to analyze temperature, H2O2 concentration and pH effects on MEA removal efficiency. The results showed that the regression model was significant (p < 0.0001), fitted well with experimental data and had a high degree of reliability and accuracy, and the data were reasonable with low errors. By analyzing interactions and solving the regression model, the maximum MEA removal efficiency was 97.90%, and the optimal conditions were defined as follows: pH 5.02, H2O2 concentration 13.41mM, and temperature 30.95 °C. Under the optimal conditions, the average MEA removal efficiency obtained from the experiments was 97.56%. This research can provide reference for the treatment of actual acetochlor industrial wastewater.
No takes yet. Share an insight, caveat, or question.
Shen et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: