Key result
Lower wearable-measured HRV is linked to greater tetanus severity, muscle spasms, and autonomic dysfunction.
Why the study?
Heart rate variability has potential clinical value in tetanus, prompting investigation into whether wearable devices can collect HRV data to assess tetanus severity.
Does heart rate variability measured from wearable devices correlate with disease severity in patients with tetanus?
Observational (n=110)
No
Does heart rate variability measured from wearable devices correlate with disease severity in patients with tetanus?
HRV measured via wearable devices is inversely related to tetanus severity and may serve as a valuable objective clinical marker in resource-limited settings.
May aid objective tetanus assessment in resource-limited settings; hypothesis-generating and requires prospective validation before practice change.
Tetanus is a disease associated with significant morbidity and mortality. Heart rate variability (HRV) is an objective clinical marker with potential value in tetanus. This study aimed to investigate the use of wearable devices to collect HRV data and the relationship between HRV and tetanus severity. Data were collected from 110 patients admitted to the intensive care unit in a tertiary hospital in Vietnam. HRV indices were calculated from 5-minute segments of 24-hour electrocardiogram recordings collected using wearable devices. HRV was found to be inversely related to disease severity. The standard deviation of NN intervals and interquartile range of RR intervals (IRRR) were significantly associated with the presence of muscle spasms; low frequency (LF) and high frequency (HF) indices were significantly associated with severe respiratory compromise; and the standard deviation of differences between adjacent NN intervals, root mean square of successive differences between normal heartbeats, LF to HF ratio, total frequency power, and IRRR, were significantly associated with autonomic nervous system dysfunction. The findings support the potential value of HRV as a marker for tetanus severity, identifying specific indices associated with clinical severity thresholds. Data were recorded using wearable devices, demonstrating this approach in resource-limited settings where most tetanus occurs.
No takes yet. Share an insight, caveat, or question.
Hai et al. (2023) conducted an observational in Tetanus (n=110). Heart rate variability (HRV) was evaluated on Tetanus severity (including muscle spasms, respiratory compromise, and autonomic dysfunction). Heart rate variability measured from wearable devices was inversely related to tetanus severity, with specific indices significantly associated with muscle spasms and autonomic dysfunction.