Implosion of wire arrays was investigated at the 1MA Zebra accelerator by multiframe laser probing and gated x-ray self-emission diagnostics. Different regimes of implosion were observed in Al and Cu wire arrays. Implosion of Al loads with masses of 33–37μg∕cm produces a dense pinch 1–1.5mm in diameter. Strong instabilities are observed in the Z pinch at the time of stagnation. Implosion of “overmassed” loads produces a plasma column 3–4mm in diameter with a core. The plasma column does not collapse during the x-ray pulse. The core of the plasma column is not subjected to the kink instability and transforms to a chain of dense spots in the later stage. Different regimes of implosion were observed in Al 8×15μm loads presumably due to variations in the current pulse and load conditions. Observed regimes are compared to three-dimensional hybrid simulation of ideal and nonideal magnetohydrodynamics modes of implosion.
No takes yet. Share an insight, caveat, or question.
Иванов et al. (2006) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: