Fractional-slot concentrated-winding (FSCW) permanent magnet synchronous machines (PMSMs) offer attractive performance advantages such as compact structure and high torque density. To achieve high performance and high reliability of high-power FSCW PMSMs, efficient thermal management remains a significant challenge. This paper presents and analyzes a mixed heat pipe cooling method, where heat pipes are integrally designed into both the stator core and windings of high-power FSCW PMSMs, enabling them to be placed as close to the heat source as possible. Furthermore, a simplified iterative optimization design method based on a lumped parameter thermal network is performed to optimize the heat pipe cooled FSCW PMSMs. The effectiveness of the mixed heat pipe cooling system in high-power FSCW PMSMs is demonstrated through the analysis, construction, and testing of a 110kW prototype. The simulated and experimental results indicate that the peak winding temperature of the prototype with the mixed heat pipe cooling system can be reduced by 29°C compared to that of the machine with the water jacket cooling method under rated conditions.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: