Accurately predicting heat flux in coarse-grained CFD-DEM simulations is a significant challenge. Specifically, the rates of fluid-particle heat exchange, the effective thermal conductivity of a bed of particles, as well as radiative heat transfer rates are difficult to predict. By using a novel algorithm, we significantly improve the accuracy and stability of such simulations by using a heat exchange limiter. This limiter enables realistic predictions even at time steps that are three orders of magnitude larger than a typical fluid heat relaxation time. Additionally, view-factor-based corrections for radiative heat exchange computations are developed. These corrections ensure an effective thermal bed conductivity with less than 3 % error for a coarse-graining ratio of 10. The applicability of the P1 radiation model in coarse-grained settings is also examined, leading to recommendations for the CFD grid resolution to ensure accurate predictions. Our methods significantly enhance stability, accuracy, and computational efficiency, making coarse-grained CFD-DEM simulations more viable for industrial applications. These advancements enable more reliable modeling of high-temperature processes, accelerate optimization studies, and enable virtual equipment design of such processes.
No takes yet. Share an insight, caveat, or question.
Mitterlindner et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: