Answers are grounded in this paper and cite their sources.
OBJECTIVE: The purpose of this article is to compare slice-encoding for metal artifact correction (SEMAC) sequences versus optimized standard MRI sequences in patients with total knee arthroplasty (TKA). SUBJECTS AND METHODS: Forty-two patients with TKA underwent 1.5-T MRI. Sequences optimized for metal implant imaging (SEMAC) were compared with standard sequences optimized with high bandwidth for STIR and proton density (PD)-weighted images. In 29 patients, CT was available as reference standard. Signal void and insufficient fat saturation were quantified. Qualitative criteria (anatomy, distortion, blurring, and noise) were assessed on a 5-point scale (1, no artifacts; 5, severe artifacts) by two readers. Abnormal imaging findings were noted. A Student t test and a Wilcoxon signed rank test was used for statistics. RESULTS: Signal void areas and insufficient fat saturation were smaller for the SEMAC sequences than for the optimized standard sequences (p ≤ 0.005 for all comparisons). Depiction of anatomic structures was better on STIR with SEMAC versus standard sequences optimized with high bandwidth (score range, 2.9-3.7 vs 4.2-4.9) and on PD-weighted imaging with SEMAC versus standard sequences optimized with high bandwidth (score range, 2.5-3.5 vs 3.1-3.8), which was statistically significant (p < 0.001 to p = 0.007 for different structures). Distortion and noise were lower for SEMAC than for the standard sequences (p ≤ 0.001), whereas no technique had a clear advantage for blurring. Detection of abnormal imaging findings was markedly increased for the SEMAC technique (p < 0.001) and was most pronounced for STIR images (98 and 74 findings for STIR with SEMAC for readers 1 and 2, respectively, vs 37 and 37 findings for readers 1 and 2, respectively, for STIR with standard sequences optimized with high bandwidth). Sensitivity for detection of periprosthetic osteolysis was improved for STIR with SEMAC (100% and 86% for readers 1 and 2, respectively) compared with STIR with standard sequences optimized with high bandwidth (14% and 29% for readers 1 and 2, respectively). CONCLUSION: SEMAC sequences showed a statistically significant artifact reduction. The detection of clinically relevant findings such as periprosthetic osteolysis was markedly improved.
No takes yet. Share an insight, caveat, or question.
Sutter et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: