Answers are grounded in this paper and cite their sources.
A series of disinfection experiments using UV radiation and ozone was performed on the secondary effluent from a wastewater treatment plant at a pilot plant scale. The microbial population in the inflowing wastewater and the treated outflow water were quantified for each of the treatment modules (fecal coliforms, fecal streptococci, Salmonella spp. (presence/absence), Clostridium Sulphite-reducers, Pseudomonas aeruginosa, Staphylococcus aureus, coliphages, nematodes, intestinal nematodes and pathogenic fungi). Treated water was stored in opaque tanks at a temperature between 20 and 22 degrees C, after which, a one-month study of the regrowth of the bacterial flora, nematodes and fungi was carried out. Clostridium Sulphite-reducers, pathogenic fungi and nematodes were the micro-organisms showing a greatest degree of resistence to UV- and Ozone-treatment. It was only concerning Clostridium and Pseudomonas abatement that significant elimination results were achieved with both technologies.
No takes yet. Share an insight, caveat, or question.
Alonso et al. (2004) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: