The standard approach to management of traumatic false aneurysms is operative. This report describes successful treatment of a traumatic peroneal artery aneurysm following a gunshot wound in a 29-year-old man by an intraluminal steel coil occlusion technique. The coil was guided through the popliteal artery and aneurysm into the distal peroneal artery via a percutaneously placed catheter: following disengagement of the coil the outflow tract of the aneurysm was occluded, and another passed and released into the proximal peroneal artery occluded the inflow tract.
No takes yet. Share an insight, caveat, or question.
Edwards et al. (1982) studied this question.