Objectives. To evaluate the viability of the possibility to use a higher D-dimer value than the one used today in the clinical algorithms evaluating patients suspected to have pulmonary embolism. Methods. A retrospective analysis of 300 serial patients for whom D-dimer values were taken during a 10 month period in the emergency room of a tertiary medical center. Results. Our analysis showed that it may be safe and cost effective to use a D-dimer value of 900 ng/ml rather than the value of 500 ng/ml accepted today, with sensitivity of 94.4%. In younger patients [under 40 years] the sensitivity reached was even higher-100%. Conclusions. Raising cutoff values of D-dimer in screening for pulmonary embolism seems a viable option. There may be a place for "tailoring" cutoff values according individual patient characteristics, such as according age groups. More studies of the subject are warranted.
No takes yet. Share an insight, caveat, or question.
Raviv et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: