Answers are grounded in this paper and cite their sources.
Battery and fuel cell simulations commonly assume that electrodes are macro-homogeneous and isotropic. These simulations have been used to successfully model performance, but give little insight into predicting failure. In Li-ion battery electrodes, it is understood that local tortuosity impacts charging rates, which may cause increased degradation. This report describes a novel approach to quantifying tortuosity based on a heat transfer analogy applied to X-ray microscopy data of a commercially available LiFePO4 electrode. This combination of X-ray imaging and image-based simulation reveals the microscopic performance of the electrode; notably, the tortuosity was observed to vary significantly depending on the direction considered, which suggests that tortuosity might best be quantified using vectors rather than scalars.
No takes yet. Share an insight, caveat, or question.
Cooper et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: