Key result
18F-FDG PET/CT detects recurrence and metastases in operated adrenocortical carcinoma with ~94% accuracy.
Why the study?
The contribution of 18F-fluorodeoxyglucose PET/CT to the re-staging of adrenocortical carcinoma was retrospectively evaluated due to limited data.
Does 18F-FDG PET/CT accurately detect local recurrence and/or distant metastases in patients with operated adrenocortical carcinoma?
Observational (n=16)
Blinded image review
No
Does 18F-FDG PET/CT accurately detect local recurrence and/or distant metastases in patients with operated adrenocortical carcinoma?
Answers are grounded in this paper and cite their sources.
18F-FDG PET/CT demonstrates high diagnostic accuracy (93.7%) for detecting recurrence or metastases in patients with previously operated adrenocortical carcinoma.
Background: The objective was to retrospectively evaluate the contribution of fluorodeoxyglucose [ 18 F] positron emission tomography/computed tomography ( 18 FDG-PET/CT) to the re-staging of adrenocortical carcinoma (ACC). Materials and methods: A total of 16 patients (10 males and 6 females), who underwent adrenalectomy due to adrenocortical carcinoma and 18 FDG-PET/CT scan to re-stage the tumor between July 2007 and April 2013, were included in the present study. The mean age was 53.37 ± 13.91 years (min: 30, max: 74) The patients were required to fast for six hours prior to scanning, and whole-body PET scanning from the skull base to the upper thighs was performed approximately 1 h after the intravenous injection of 555 MBq of F-18 FDG. Whole body CT scanning was performed in the cranio-caudal direction. FDG-PET images were reconstructed using CT data for attenuation correction. Suspicious recurrent or metastatic lesions were confirmed by histopathology or clinical follow-up. Results: Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 18 FDG-PET/CT were 100%, 83.3%, 90.9%, 83.3%, and 93.7%, respectively. Conclusion: 18 FDG-PET/CT detects local recurrence and/or distant metastases with high accuracy in the re-staging of operated adrenocortical carcinoma. It is considered that the procedure could play an important role in treatment decision after the operation and post-operative follow-up and could influence the entire decision-making process.
No takes yet. Share an insight, caveat, or question.
Hakan Öztürk (2024) conducted an observational in Adrenocortical carcinoma (n=16). 18F-FDG PET/CT vs. Histopathology or clinical follow-up was evaluated on Diagnostic accuracy (sensitivity, specificity, PPV, NPV, accuracy). 18F-FDG PET/CT detected local recurrence and distant metastases with 100% sensitivity, 83.3% specificity, and 93.7% accuracy in the restaging of operated adrenocortical carcinoma.
Synapse has enriched 10 related papers. Consider them for comparative context: