This is the authors' abstract. We don't add key points for this paper.
Carbon contamination of optics is a serious issue in all soft X-ray beamlines because it decreases the quality of experimental data, such as near-edge X-ray absorption fine structure, resonant photoemission and resonant soft X-ray emission spectra in the carbon K-edge region. Here an in situ method involving the use of oxygen activated by zeroth-order synchrotron radiation was used to clean the optics in a vacuum ultraviolet and soft X-ray undulator beamline, BL-13A at the Photon Factory in Tsukuba, Japan. The carbon contamination of the optics was removed by exposing them to oxygen at a pressure of 10(-1)-10(-4) Pa for 17-20 h and simultaneously irradiating them with zeroth-order synchrotron radiation. After the cleaning, the decrease in the photon intensity in the carbon K-edge region reduced to 2-5%. The base pressure of the beamline recovered to 10(-7)-10(-8) Pa in one day without baking. The beamline can be used without additional commissioning.
No takes yet. Share an insight, caveat, or question.
Toyoshima et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: