Key result
Cycle tests to volitional exhaustion at varying intensities yielded similar respiratory characteristics at termination, including a breathing frequency of 49 breaths/min.
Why the study?
The effect of exercise intensity on the time and flow characteristics of the respiratory cycle at volitional exercise termination was examined to understand breathing integration and exercise capacity.
Does exercise intensity affect the time and flow characteristics of the respiratory cycle profile at volitional exercise termination in non-elite athletes?
Does exercise intensity affect the time and flow characteristics of the respiratory cycle profile at volitional exercise termination in non-elite athletes?
The integration of timing and flow during breathing, which converge to similar characteristics at exercise termination regardless of intensity, influences exercise capacity in non-elite athletes.
Answers are grounded in this paper and cite their sources.
Similar respiratory termination profiles across intensities may influence capacity; leaves open intensity-specific mechanisms in non-elite athletes.
In this study, we examine the effect of exercise on the time and flow characteristics of the respiratory cycle profile at the point of volitional exercise termination. Eight males (mean age 29 years, s = 10; body mass 74 kg, s = 7; height 1.75 m, s = 0.04) undertook a cycle test to volitional exhaustion on a cycle ergometer, which allowed peak oxygen uptake (VO(2peak)) to be measured (mean 51 ml x kg(-1) x min(-1), s = 7). At a later date, two sub-maximal tests to volitional exhaustion were completed in a random order at 76% (s = 6) and 86% VO(2peak) (s = 7). As expected, the magnitude of the respiratory flow and time characteristics varied with the three exercise intensities, as did the point of exercise termination and terminal ventilation rates, which varied from 7 to 27 min and 112 to 132 litres x min(-1) respectively. More importantly, however, at exercise termination some of the characteristics were similar, particularly the breathing frequency (at termination 49 breaths x min(-1)), the ratio between inspiration and total breath time (0.5), and the later occurrence of peak inspiratory flow (0.24-0.48 s). The coincident unity of these time and flow profile characteristics at exercise termination illustrates how the integration of timing and flow during breathing influence exercise capacity in non-elite athletes.
No takes yet. Share an insight, caveat, or question.
Kift et al. (2007) studied Healthy non-elite athletes (n=8). Cycle tests to volitional exhaustion at 76% and 86% VO2peak vs. Different exercise intensities was evaluated on Respiratory time and flow profile characteristics at volitional exercise termination. Cycle tests to volitional exhaustion at varying intensities yielded similar respiratory characteristics at termination, including a breathing frequency of 49 breaths/min.
Synapse has enriched 10 related papers. Consider them for comparative context: