Chinese ancient timber structures highly rely on the complex Dougong system for vertical load transfer. However, previous studies have mostly focused on individual Dougong, lacking a quantitative understanding of the synergistic load-bearing mechanism and system-level mechanical behavior of the entire Dougong group. This study investigates the one Dou and two Sheng Dougong group from the Qing-dynasty Jiayuguan architecture using three sets of full-scale experiments and refined ABAQUS finite element analysis (FEA). Test results indicate the failure sequence proceeds from the pingban-Fang to the column top, and finally Dougong. The overall macroscopic failure transitions from compression splitting of pingban-Fang in short spans to deflection-controlled failure in long spans. The load-displacement curves of the Dougong group fit a bilinear model, with vertical stiffness negatively correlated to span and intercolumnar Dougong count. FEA reveals a load-sharing ratio of approximately 9:1 between column-top and intercolumnar Dougong, with the tuo-Beam bearing roughly 75% of the load within the column-top set. Parametric analysis confirms span as the primary factor affecting vertical stiffness. These findings provide the first quantitative data on the synergistic mechanism of Dougong groups, offering a more reliable theoretical basis and computational approach for assessing and conserving Qing-dynasty timber structures.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.