Key result
Hybrid cores and closed magnetic circuits complement each other for mixed-flow VAD development in vitro.
Why the study?
Previous strategies for rotor suspension in a mixed-flow type VAD used magnetic bearings with active control in only one degree of freedom, requiring improved magnetic bearing solutions.
The development of hybrid magnetic bearings with single-axis control shows promising in vitro performance for mixed-flow ventricular assist devices.
May advance hybrid magnetic bearing designs for mixed-flow VADs; hypothesis-generating and requires in vivo validation before clinical translation.
In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in which the active control is executed in only one degree of freedom, in the axial direction of the rotor. Remaining degrees of freedom, excepting the rotation, are restricted only by the attraction force between pairs of permanent magnets. This study is part of a joint project in development by IDPC and Escola Politecnica of São Paulo University, Brazil. This article shows advances in that project, presenting two promising solutions for magnetic bearings. One solution uses hybrid cores as electromagnetic actuators, that is, cores that combine iron and permanent magnets. The other solution uses actuators, also of hybrid type, but with the magnetic circuit closed by an iron core. After preliminary analysis, a pump prototype has been developed for each solution and has been tested. For each prototype, a brushless DC motor has been developed as the rotor driver. Each solution was evaluated by in vitro experiments and guidelines are extracted for future improvements. Tests have shown good results and demonstrated that one solution is not isolated from the other. One complements the other for the development of a single-axis-controlled, hybrid-type magnetic bearing for a mixed-flow type VAD.
No takes yet. Share an insight, caveat, or question.
Silva et al. (2011) studied Ventricular assist device development. Single axis controlled hybrid magnetic bearing solutions was evaluated on In vitro evaluation of pump prototypes. In vitro experiments demonstrated that two hybrid magnetic bearing solutions (hybrid cores and closed magnetic circuit) complement each other for the development of a mixed-flow ventricular assist device.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More on Mechanical circulatory supportMore from Artificial Organs