Answers are grounded in this paper and cite their sources.
A detailed analysis is carried out of the electric field induced in a cell when the body is exposed to an incident axial electric field at 50--60 Hz. It is shown that the field in a spherical cell is effectively shielded by the membrane so that the induced field in its interior is negligibly small. It is also shown that the induced electric field in a cylindrical cell (which is long compared to its radius) is the same as the axial field outside the cell. In this case, the cell membrane has no shielding effect.
No takes yet. Share an insight, caveat, or question.
King et al. (1998) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: