Key result
Minimally invasive trans-thoracic LV needle biopsy proves safe and yields high-quality tissue in dogs.
Why the study?
Myocardial biopsies are important to study molecular mechanisms of cardiac disease, but methods enabling repetitive sampling in individual adult dogs were not established.
Is a minimally invasive trans-thoracic approach for serial left-ventricular biopsies safe and feasible in adult dogs?
Is a minimally invasive trans-thoracic approach for serial left-ventricular biopsies safe and feasible in adult dogs?
A minimally invasive trans-thoracic approach for serial left-ventricular biopsies in dogs is safe, feasible, and yields suitable samples for molecular analysis without affecting cardiac function.
Enables serial molecular sampling in canine models without cardiac harm; leaves open translation to human protocols.
Myocardial biopsies are an increasingly important tool to unravel the molecular mechanisms of cardiac disease. We evaluate a novel minimally invasive trans-thoracic approach for left-ventricular (LV) intra-mural biopsies, which enables repetitive individual sampling in adult dogs. Forty three generally anaesthesised dogs were studied during sinus rhythm (SR, control) and multiple times after the induction of volume overload hypertrophy (complete atrioventricular block [AVB]). Through a small cutaneous incision, an automatic biopsy needle was advanced into the apicolateral LV, guided by fluoroscopy. Electrocardiography (ECG), LV pressure and echocardiography served to monitor the procedure. One hundred eighty-eight intra-mural LV biopsies were obtained in 82 serial experiments (usually SR, 1, 2 and 6 weeks AVB) with a maximum of 8 repeated biopsies. All biopsies ( approximately 10 mm(3)) were suitable for simultaneous application of different cell-biological (light and electron microscopy, immunohistochemistry) and molecular techniques (PCR, Western blotting). In chronic experiments, repeated biopsy sampling did not influence haemodynamics, mechanics, electrocardiographic parameters or myocardial remodelling during SR or AVB. The rate of significant complications was as low as 4% of experiments. Minimally invasive sampling of LV needle biopsies enables serial assessment of myocardial remodelling using different molecular techniques in individual animals. The technique is safe and has no long-term effects on cardiac function or structure.
No takes yet. Share an insight, caveat, or question.
Donker et al. (2007) studied Cardiac hypertrophy (experimental model) (n=43). Minimally invasive trans-thoracic left-ventricular biopsy sampling vs. Non-bioptised dogs was evaluated on Safety, feasibility, and impact on cardiac function/structure. Minimally invasive trans-thoracic sampling of left-ventricular needle biopsies in adult dogs is safe, yields high-quality tissue, and has no long-term effects on cardiac function or structure.