This is the authors' abstract. We don't add key points for this paper.
This study focuses on the use of a heterogeneous catalyst Ni/Ce0.58Zr0.42O2 to study the Sabatier reaction in conventional catalytic thermal heating and the dielectric barrier discharge plasma‐catalytic process. Its aim is to study the threshold temperature of the Sabatier reaction in plasma conditions. A set of experiments with different inlet flow rates is carried out in a plasma reactor to investigate the steady‐state temperature of the reaction. To estimate the threshold temperature of the Sabatier reaction more accurately, the temperature difference between the catalytic bed and the external surface of the reactor is calculated and simulated in COMSOL Multiphysics® software. Finally, the threshold temperature of the Sabatier reaction during plasma processing is assumed to be 116°C, based on the experimental data and simulation analysis.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: