A sensitivity-improved fiber-optic strain sensor using an etched and regenerated fiber Bragg grating (ER-FBG) suitable for a large range of temperature measurements has been proposed and experimentally demonstrated. The process of chemical etching (from 125 µm to 60 µm) provides regenerated gratings (at a temperature of 680 °C) with a stronger reflective intensity (from 43.7% to 69.8%), together with an improved and linear strain sensitivity (from 0.9 pm/με to 4.5 pm/με) over a large temperature range (from room temperature to 800 °C), making it a useful strain sensor for high temperature environments.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2014) studied this question.