In the present research, laundry wastewater treatment is studied using the electrocoagulation/electroflotation process. For the optimization of treatment conditions such as electrode type (Al–Al, Al–Fe, Fe–Fe, and Fe–Al), initial pH (5–9), current (0.54–2.16 A), and application time (15–60 min), response surface methodology is used. Removal efficiencies of chemical oxygen demand (COD), color, anionic surfactant, microplastic, and phosphate are studied. It is determined that the most effective removal is obtained with 2.16 A current, pH 9, and 60 min reaction time using Fe–Al electrode. Here, 91%, 94%, 100%, and 98% removal efficiencies are achieved for COD, surfactant, color, and microplastic, respectively. The operating cost of the combined process is calculated as $1.32 m−3for the optimum removal parameters. The adsorption kinetics study shows that the removal follows second‐order kinetics. The laboratory‐scale test results indicate that the electrocoagulation/electroflotation process is feasible for the treatment of laundry wastewater.
No takes yet. Share an insight, caveat, or question.
Akarsu et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: