The oxygen permeability and stability of a perovskite oxide membrane of nominal composition Sr 0.95 Co 0.8 Fe 0.2 O 3 - δ were investigated in an atmosphere containing CO 2 and H 2 O. It was observed that, at a temperature of 810 °C, the oxygen permeation flux through the membrane decreased significantly with time when an air stream containing both CO 2 and H 2 O impurities was used as the feed gas and the membrane partially decomposed, whereas in air containing either CO 2 or H 2 O species alone, the oxygen flux decreased slightly and the membrane retained its phase composition and microstructure. It was also found that, at a higher temperature of 900 °C, the oxygen flux was almost unaffected by the presence of these species and the membrane remained intact. The effects of CO 2 and H 2 O were explained in terms of formation of bicarbonate on the membrane surface, and optimal operation conditions for the membrane were proposed.
No takes yet. Share an insight, caveat, or question.
Yi et al. (2005) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: