A nearly two-octave wide coherent mid-infrared supercontinuum is demonstrated in a dispersion-engineered step-index indium fluoride fiber pumped near 2 µm. The pump source is an all-fiber femtosecond laser with 100 fs pulse width, 570 mW average power and 50 MHz repetition rate. The supercontinuum spectrum spans from 1.25 µm to 4.6 µm. Numerical modelling of the supercontinuum spectra show good agreement with the measurements. The coherence of the supercontinuum is calculated using a numerical model and shows a high degree of coherence across the generated bandwidth allowing it to be used for frequency comb applications.
No takes yet. Share an insight, caveat, or question.
Salem et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: