Answers are grounded in this paper and cite their sources.
This paper presents a time-domain statistical identification method for synchronous-machine linear parameters from the standard line-to-line short-circuit test. The measurements are recorded on a 13.75-MVA hydrogenerator at Hydro-Quebec's Rapide-des-Quinze generating station. A complete mathematical model for synchronous machine asymmetrical test analysis is proposed. An efficient algorithm is built to accurately calculate the standard equivalent circuit from time-constants and operational inductances. The maximum likelihood estimator derived from the generalized least-squares method is then used for parameter identification. Validation of the estimated model response against the measured running-time domain data confirms the effectiveness of the proposed estimation technique.
No takes yet. Share an insight, caveat, or question.
Wamkeue et al. (1999) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: