Key result
Ultrasound-guided percutaneous lower brachial artery closure using ProGlide/ProStyle yields 0% reintervention.
Why the study?
The efficacy and safety of ultrasound-guided suture-based ProGlide/ProStyle closure device for brachial artery access closure after interventional radiology procedures were not well established.
Does ultrasound-guided ProGlide/ProStyle deployment safely and effectively close brachial artery access after interventional procedures?
Observational (n=21)
No
Does ultrasound-guided ProGlide/ProStyle deployment safely and effectively close brachial artery access after interventional procedures?
Ultrasound-guided ProGlide/ProStyle deployment for brachial artery closure is safe and effective, avoiding major vascular complications in a small cohort.
The aim of the study was to evaluate the efficacy and safety of ultrasound-guided suture-based ProGlide/ProStyle closure device for brachial artery access closure after interventional radiology procedures. A modified technique of ProGlide/ProStyle percutaneous suture deployment with ultrasound guidance was used for brachial artery access closure (23 procedures in 21 patients) between June 2019 and June 2024. The only exclusion criterion was a brachial artery diameter of less than 4 mm. The primary outcome measure was the incidence of reintervention from device failure and the secondary outcome measure was the incidence of brachial access site complications. Ultrasound appearances of the brachial artery immediately and 1 day after access site closure were documented, and clinically followed up 60 days after access site closure. There was successful closure in all arteries, and none required access site reintervention. There were no major vascular complications in any of our cases. There were no major access site–related complications. Ten of 23 (43.5%) cases showed vasospasm cranial to the closure site on ultrasound, which disappeared on the follow-up ultrasound performed the day after access site closure. This novel ultrasound-guided ProGlide/ProStyle deployment for brachial vascular closure is efficacious and safe.
No takes yet. Share an insight, caveat, or question.
Premnath et al. (2025) conducted an observational in Brachial artery access closure after interventional radiology procedures (n=21). Ultrasound-guided suture-based ProGlide/ProStyle closure device was evaluated on Incidence of reintervention from device failure. Ultrasound-guided percutaneous lower brachial artery access closure using a ProGlide/ProStyle device resulted in successful closure in all 23 procedures with 0% requiring reintervention.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: